Hall Pyke

The SMART choice for filtration

  • Home
  • Products
    • Col 1
      • Backwashing and self-cleaning filters
      • Capsule Filtration
      • Compressed Air Filters
      • Depth Pre Filtration
      • Dust Filter Cartridges
      • Filter Bags
      • Filter Housings
    • Col 2
      • Fluid Bed Dryer Filters
      • Gas Filtration
      • High Flow
      • HVAC
      • Hygienic Strainers
      • Liquid Bag Filtration
      • Magnetic Filters
    • Col 3
      • Membrane Filtration
      • Single Use Systems
      • Stainless Steel Filters
      • Stainless Steel Mesh Fabrication
      • Steam Filtration
      • Surface Pre Filtration
      • Water Treatment
  • Services
    • Lab Support Services
    • Filter Integrity Test
    • Filterability Testing
    • Filter Validation
    • Customer Support
    • Leak Detection Test for Baghouses
  • Downloads
    • Hall Pyke Publications
    • Company Downloads
    • How-Tos
  • News
  • Why Us
  • Gallery
  • Contact Us
Home / Industries / Pharmaceutical / FluoroPV Hydrophilic PVDF

FluoroPV Hydrophilic PVDF

FluoroPV Hydrophilic PVDF

FluoroPV Filter Cartridges are composed of a unique hydrophilic polyvinylidene fluoride (PVDF 0.2 membrane) membrane characterized by low extractable and protein binding. The FluoroPV Filter Cartridges that are made up of a PVDF 0.2 membrane are suitable for the sterilized filtration of pharmaceutical liquids including ophthalmic liquids, biological and other diluted preservative solutions.

Features and Benefits

  • Low extractable and protein binding
  • Broad chemical compatibility and temperature resistance
  • Excellent durability proven by testing forward/reverse pulse up to 100x
Categories / Industries:
Chemicals and Coatings, Dairy, Food and Beverage, Membrane Filtration, Pharmaceutical, Utilities, Water Treatment


Details

Email Us Call Us
  • Description

Description

Quality Standards

  • Bacterial quantitative retention of 107 CFU/cm2 Brevundimonas
  • Diminuta (ATCC 19146) according to ASTM F838 methodology
  • 100% Integrity testing in manufacturing
  • Each filter is fully traceable with unique serial number
  • Manufactured in a facility which adheres to ISO 9001:2015 Practices

Full Regulatory Compliance with following

  • Bacterial Endotoxin: Aqueous extraction of autocalved filter contains <0.25 EU/ml as determined by Limulus Amebcyte Lysate (LAL), USP<85>.
  • Non-fiber Releasing: Component materials meet the criteria for a “ Non-fiber-releasing filter ” as defined in 21 CFR 210.3(b)(6).
  • Component Material Toxicity:
    Meet the requirement of USP <87> In Vitro Cytotoxicity Test ;
    Meet the Criteria of USP<88> Biological Reactivity Test for Class VI-121°C plastics
  • TOC/Conductivity at 25 °C:Autoclaved filter effluent meet the USP<643> for Total Organic Carbon and USP<645> for Water Conductivity per WFI requirements after a UPW flush of specified volume.
  • Particle Shedding: Autoclaved filter effluent meet the USP<788>for large volume Injections.
  • Indirect Food Additive: All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.

Typical Applications

  • Antibiotics
  • Aggressive Solvents
  • Biological Agents
  • Blood Products
  • Chemicals
  • Cold and Hot WFI
  • Ophthalmic Solutions
  • Sanitizing Agents

Materials of Construction

Filter Media LHPVND: Single-Layer Hydrophilic PVDF Sterile Membrane
DLHPVNDR: Double-Layer Hydrophilic PVDF Sterile Membrane
Support Polypropylene
Cage/Core/End Caps Polypropylene

Operating Conditions

Max. Operating Pressure 6.9 bar (100 psi) at 25 °C
4.0 bar (58 psi) at 60 °C
2.4 bar (35 psi) at 80 °C
Max. Differential Pressure Forward 6.9 bar (100 psi) at 25 °C
4.0 bar (58 psi) at 60 °C
2.4 bar (35 psi) at 80 °C
Reverse 3.0 bar (44 psi) at 25 °C
1.0 bar (15 psi) at 80 °C
Effective Filtration Area 0.58m²/ Φ 69-10 inch

Sterilization

Inline Steam Sterilization (LHPVND & DLHPVNDR) Up to 100 forward cycles and 50 reverse cycles (135 °C for 30 min < 0.3 bar per cycle)
“Autoclave (LHPVND & DLHPVNDR) “ up to 400 cycles (130°C for 30min per cycle)

Ordering Information

LHPVND Removal Ratings End Cap Nominal Length Seal Material
[Single-Layer] 0010 = 0.10µm HSF = 226/Fin (PBT Insert) 05 = 5″ S = Silicone
0022 = 0.22µm HSC = 226/Flat (PBT Insert) 10 = 10″ E = EPDM
0045 = 0.45µm HTF = 222/Fin (PBT Insert) 20 = 20″ V = Viton
0065 = 0.65µm HTC = 222/Flat (PBT Insert) 30 = 30″ P = PFA/Viton
0100 = 1.0µm DOE= Double Open End 40 = 40″
“DLHPVNDR [Double-Layer]”
2222 = 0.22+0.22µm
2245 = 0.22+0.45µm”
6545 = 0.65+0.45µm
2210 = 0.22+0.1µm
4545 = 0.45+0.45µm
6522 = 0.65+0.22µm
6510 = 0.65+0.1µm
4510 = 0.45+0.1µm
  • Pages

    • All Downloads
      • Company Downloads
      • Hall Pyke Publications
      • How-Tos
    • Checkout
      • Purchase Confirmation
      • Purchase History
      • Transaction Failed
    • Clients
    • Contact Us
    • Customer Support
    • Download locked
    • Front-page-test
    • Gallery
    • Lab Support Services
      • Filter Integrity Test
      • Filter Validation
      • Filterability Testing
      • Leak Detection Test for Baghouses
    • Message from Andrew
    • News
    • Our Product Range
    • Privacy & Cookie Policy
    • Request a Callback
    • Request a Quote
    • SMART
    • Suppliers
    • Support Videos
    • Vacancies
    • Welcome
    • Welcome to Hall Pyke
    • Why Us
  • Archives

    • March 2022
    • December 2021
    • November 2021
    • October 2021
    • September 2021
  • Categories

    • Uncategorized (8)

Get in Touch!

Hall Pyke

The SMART choice for filtration

T: +353-1-4501411
E: info@hallpyke.ie

Contact Us
Terms & Conditions
Cookie Policy
Privacy Policy